A new BTO flat comes without air-conditioning. HDB provides the wiring to aircon points and an aircon ledge for the outdoor units; the system is yours to choose. NEA's 2017 household energy study found air-conditioners to be the largest single use of electricity in Singapore homes, so the choice shows in every bill after it.

This guide explains the words you will meet in a showroom (System 1 to 4, ticks, inverter, kW and Btu) with NEA's and HDB's own rules, and what they mean for a new flat.

System 1, 2, 3, 4: what the numbers mean

In Singapore's shops, "System" and a number describe a split air-conditioner by how many indoor units share one outdoor unit. A System 1 is a single split: one indoor unit and one outdoor unit. A System 4 runs four indoor units, say the living room and three bedrooms, from one outdoor unit. These are the trade's names, used by manufacturers such as Daikin and Panasonic; NEA's rules call them single-split and multi-split air-conditioners.

HDB's renovation rules shape the choice. In a flat with a 40-amp main switch, which HDB calls higher electrical loading, at most two split-type condensing units may be installed. They go on the aircon ledge, never along the common corridor, and the piping must run inside the flat. Try the combinations for a 4-room flat below.

Which rooms share an outdoor unit: a real 4-room flat
  • Outdoor unit 1: System 3 (multi-split) living and dining, bedroom 1, bedroom 2
  • Outdoor unit 2: System 1 (single split) main bedroom

2 outdoor units: within HDB's limit of two condensing units. Every multi-split on sale today has 5 ticks; a single split has 4 or 5 (NEA).

Each colour is one outdoor (condensing) unit on the air-con ledge and the rooms it serves. HDB's renovation guidelines (24 July 2026) allow at most two split-type condensing units in a flat with a 40-amp main switch, on the ledge only, with the piping run inside the flat. The routes are our illustration, laid so that none crosses another; your installer decides the real run. Drawing: BTOLeh, from its Lakeview Cascadia model, with BTOLeh's overlay.
The façade of HDB Block 506 in Bishan, with aircon condensing units on its ledges
Condensing units on the ledges of an HDB block. In a new flat, HDB allows at most two. Photo: MapStaringEnthusiast, CC0 1.0, via Wikimedia Commons

Ticks: what the energy label rates

Every household air-conditioner sold in Singapore carries NEA's energy label, which rates its efficiency from 1 tick (low) to 5 ticks (excellent). For an inverter split unit the rating is based on its weighted coefficient of performance (COP), the cooling it gives for each unit of electricity: 40% of its COP at full load plus 60% of its COP at half load.

Since 1 April 2025 the law sets a minimum: a new single split must have at least 4 ticks (a weighted COP of 4.86 or more) and a multi-split must have 5 ticks (5.50 or more). So every System 2, 3 or 4 on sale today is a 5-tick unit, and a System 1 has 4 or 5 ticks.

NEA consulted from 21 October to 9 November 2026 on replacing the tick scale, for every regulated appliance, with a simpler two-tier label and a QR code by 2028. That is a proposal for now.

From efficiency to ticks: an inverter single split
Weighted COP 5.48: 4 ticks
NEA's tick rating (1 July 2026): weighted COP = 0.4 × COP at full load + 0.6 × COP at half load. A single split needs 4.86 for 4 ticks and 5.50 for 5, with a standby-power limit too; since 1 April 2025 nothing below 4 ticks may be sold. COP is the cooling given for each unit of electricity.

Reading the label's kWh and dollars

Besides the ticks, the label gives the model's annual energy use in kWh and an estimated annual cost. Both assume 8 hours of use a day plus 16 hours on standby, and the cost is worked out at 27 cents per kWh. For a multi-split, only the outdoor unit's model number is shown.

SP Group's household tariff for October to December 2026 is 31.16 cents per kWh with GST, so at today's price the label's dollars are about 15% low, before any difference in how many hours you actually run it. Use the label to compare models with each other, not to predict a bill.

What the label says, and what it means at today's price

Cost a year. The same use at a fixed 27 cents per kWh, not today's tariff.

On the label, at 27 ¢ a kWhS$270
At today's 31.16 ¢, 8 hours a dayS$312
For your 8 hours a day, aboutS$312
NEA, The Energy Label (1 July 2026); SP Group's household tariff for October to December 2026, 31.16 cents per kWh with GST. The label is an example drawn by BTOLeh to show the parts NEA lists, with made-up figures: it is not NEA's artwork or a real model. Scaling by hours is rough: it ignores standby use and how hard the unit works.

Inverter or non-inverter

NEA's definitions are short. An inverter air-conditioner varies its compressor's output by means other than switching on and off; a non-inverter varies it by switching on and off. Manufacturers add that switching on and off uses more electricity; NEA's pages do not say so themselves.

The difference shows in the rating: an inverter unit is rated on its weighted COP, which counts its efficiency at half load, while a non-inverter is rated at full load only and must reach the same figures for 4 or 5 ticks.

How each varies its output
FullOffMinutes after switching on (0 to 60)
Non-inverter: on and off Inverter: varies its output
An illustration of NEA's definitions, not measured data: a non-inverter varies its compressor's output by switching it on and off; an inverter varies it by other means, here running on at part output once the room is cool.

Sizing: NEA's floor-area rule

NEA's rule of thumb is that the cooling capacity you need, in kilowatts, is the floor area to be air-conditioned in square metres divided by 5. To convert to the British thermal units per hour (Btu/h) that many shops quote, multiply the kW by 3,412.

Getting it wrong either way costs: NEA says oversized and undersized air-conditioners run less efficiently, and an oversized one costs more to run and may not dehumidify the room properly. A bigger unit may be needed for a room with a lot of glass, east- or west-facing windows, a double-height ceiling or extra sources of heat. On a multi-split the total is usually the sum of the rooms, but a smaller total can do if the rooms are not all cooled at once. For a detailed assessment, NEA says to ask your supplier.

NEA's rule on a real flat: square metres ÷ 5 = kW

Total: 32 m² ÷ 5 = 6.4 kW, about 21,800 Btu/h. On a multi-split a smaller total can do if the rooms are not all cooled at once.

NEA, Tips on buying energy-efficient appliances (11 November 2026): cooling capacity in kW = floor area in m² ÷ 5; Btu/h = kW × 3,412, rounded here. The room areas are BTOLeh's estimates from its drawing of this flat (the brochure gives no room sizes): measure your own. Rooms with a lot of glass, east- or west-facing windows or high ceilings may need more; ask your supplier. Drawing: BTOLeh, from its Lakeview Cascadia model, with BTOLeh's overlay.

Before you buy

  • Measure each room on the brochure's floor plan with its scale bar; the brochure's floor area is for the whole flat and includes the aircon ledge.
  • Note which rooms face east or west; our stack guide explains when the sun reaches them.
  • Ask for the full-load cooling capacity in kW, which is what the label states.

Using it well: NEA's own figures

NEA's tips for households put numbers on the savings. Its figures assume a 4-tick, 2.6 kW single split and a 50 W fan, at 29 cents per kWh before GST.

What NEA suggests

  • Set the temperature at 25 °C. Each degree higher saves about 3% of utility costs.
  • Run the aircon for an hour, then switch to a fan: about 23% saved.
  • Use a fan instead of the aircon: about 26% saved.
  • Set the timer to turn it off half an hour earlier than usual: about 2% saved.
  • Check the filter once a month, and have the units serviced and inspected every year.
  • Close curtains or blinds during the hottest part of the day, or use solar window film.

Climate Vouchers and Tengah's central cooling

Under the Climate Friendly Households Programme, Singapore Citizen and permanent resident households registered at an HDB flat can claim $400 of Climate Vouchers, a $300 set and a $100 set that can be combined in one purchase. Air-conditioners with 5 ticks are among the eligible products. The vouchers must be claimed and used by 31 December 2027; the programme's pages do not say how they apply to a flat you have not yet collected.

In Tengah, HDB has contracted Keppel to pipe chilled water from central chillers to 12 BTO projects, about 14,000 homes, so that residents who opt in need no condensers of their own; HDB says it uses up to 30% less energy. The flats there still have aircon ledges for residents who prefer their own system.

See it in the explorer

Estimate the aircon for a real BTO home

The explorer's Electricity estimation tab works out, room by room, what a chosen home's aircon may cost to run each month: from the sun that reaches its windows, for the rooms, hours and set point you choose, with the setups above compared side by side, then the rest of the bill beside it. It is an estimate, and says so.

Free for everyone: every project's 3D precinct at noon, building labels and nearby places, and homes coloured by flat type. The feature shown comes with a project or a whole launch.

Explore a project in 3D, freeWhat is free and what is paid

Recorded in BTOLeh's explorer.

Sources

  1. NEA: Tick rating (1 July 2026)
  2. NEA: The energy label (1 July 2026)
  3. NEA: About Mandatory Energy Labelling and Minimum Energy Performance Standards (19 August 2026)
  4. NEA: Minimum energy performance standards (23 October 2026)
  5. NEA: Regulated goods (inverter and non-inverter definitions) (26 August 2026)
  6. NEA: Tips on buying energy-efficient appliances (sizing) (11 November 2026)
  7. NEA: Energy saving tips by appliance (19 August 2026)
  8. NEA news release: Four in five households motivated to save energy if they can save money: NEA study (5 May 2018)
  9. NEA news release: Enhancing energy efficiency requirements of home appliances (2 March 2023)
  10. REACH: Public consultation on the revamp of the Mandatory Energy Labelling Scheme (21 October to 9 November 2026)
  11. Climate Friendly Households Programme: Climate Vouchers: air-conditioners (updated 18 June 2026)
  12. Climate Friendly Households Programme: Climate Vouchers: frequently asked questions (16 October 2026)
  13. HDB: Renovation guidelines for air conditioner installation works (24 July 2026)
  14. HDB press release: HDB awards new centralised cooling system contract to Keppel for 9 BTO projects in Tengah (16 April 2026)
  15. SP Group: Tariff information
  16. Daikin Singapore (manufacturer): Air conditioning 101 (the meaning of System 1 to 4) (31 May 2024)
  17. Panasonic Singapore (manufacturer): Decoding aircon terms and types: a glossary